How to Reset a Well Pump (Pressure Switch Lever and Other Resets)

Boreholeflow is reader supported. When you buy through links on this page, I may earn a commission at no extra cost to you. Read the full disclosure.

Quick answer
  • Most well pumps with a lever on the pressure switch reset like this: lift the lever to START, hold it until the gauge passes the cut in pressure, then let go to AUTO.
  • The lever only trips when pressure falls about 10 psi below cut in, so find out why it dropped: a power cut, a leak or a low water level.
  • Constant pressure drives and pump protectors usually restart on their own after a delay. A power cycle at the breaker clears most faults.
  • Reset any device once. If it trips again, stop and find the cause before you burn out the pump.

Your taps are dry, the pressure gauge reads zero and the pump is silent. Very often the pump is fine and a safety device has simply shut it off, so a reset brings the water back in a minute.

This guide shows how to reset each common device: the pressure switch lever, constant pressure drives, pump protectors, control boxes, jet pump motors and the breaker. The reset finder below gives you the right steps for what you have.

Well pump reset finder

Well pump reset finder

Pick what you see at your pressure tank or panel. We show how to reset it safely and when to stop.

Safety first

Most well pumps run on 230 or 240 volts, and the pressure switch terminals stay live while the breaker is on. Never touch anything under the switch cover with the power on.

You can lift the reset lever with the cover on, because it is outside the switch. Keep a dry footing, and call a licensed pump installer for anything electrical you are not sure of.

How to reset a well pump pressure switch with a lever

The lever is part of a low pressure cutoff. According to Square D, the switch trips when system pressure falls 10 psi below the cut in setting and stays off until someone resets it by hand.

  1. Find the switch. It sits on a short pipe near the pressure tank, with a gray cover and a small lever on the side.
  2. Check the gauge. A reading near zero or well below your cut in pressure confirms the cutoff has tripped.
  3. Close the taps. Make sure no one is running water, and look for an obvious leak or burst pipe.
  4. Lift the lever to START and hold it. You will hear the pump start.
  5. Watch the gauge climb. Hold until pressure passes the cut in setting, for example 30 psi on a 30/50 switch or 40 psi on a 40/60 switch.
  6. Let go. The lever returns to AUTO and the pump runs on to the cut out pressure, then stops.
Switch settingCuts out at low pressureHold the lever until the gauge passes
20/40About 10 psi20 psi
30/50About 20 psi30 psi
40/60About 30 psi40 psi

Cutoff points from Boshart and Square D. Check the label inside your switch cover for its range.

If the gauge does not move within about a minute, release the lever. A pump that runs without building pressure may be dry, air locked or broken, and holding the lever longer will only overheat it.

See low pressure cutoff switches on Amazon

Why the pump shut off

A low pressure cutoff does its job when pressure falls far below normal. Resetting it brings water back, but find out what caused the drop so it does not happen again.

Likely causeWhat points to itWhat to do
Power cut or a tripped breakerEverything else in the house lost power tooReset once power is back; the switch cannot restart itself
Big water drawIrrigation, filling a pool or a long shower sessionSpread out heavy use; see how to test well flow rate
Leak in the house or yard linePressure falls when all taps are closedFind the leak; see low water pressure from a well
Low water levelAir or sputtering at taps before the cutoffSee signs your well is running dry
Clogged switch tubeErratic switching, readings that do not match the gaugeClear the nipple under the switch with the power off
Worn pumpPressure climbs slowly or stalls below cut outSee signs your well pump is going bad

How to reset a constant pressure controller

Constant pressure systems use a drive that changes the motor speed. When something goes wrong, the drive stops the pump and shows a fault code or a pattern of lights.

  • Read the code first. The manual or the label on the drive lists what each code means, such as dry well, underload, overheat or overcurrent.
  • Give it time. Many drives restart on their own after a fault delay, which can be several minutes.
  • Power cycle it. Turn the breaker off, wait about a minute and turn it back on to clear most faults.
  • Check the drive vents. An overheated drive in a hot garage or a dusty corner may trip again until it can breathe.

Thinking of switching to one of these systems? See the best constant pressure systems.

How to reset a pump protector

A pump protector watches the motor current and shuts the pump off if it runs dry. It then waits a set recovery time before trying again, which gives a slow well time to refill.

Most models reset when you cycle the power or press a reset button, and many have a dial for the restart delay. If it trips often, your well cannot keep up with demand; see well pump protection devices.

See pump protectors on Amazon

Control boxes and jet pump motors

On a 3 wire submersible, some larger control boxes have a red overload button. Turn the power off, let it cool for a few minutes, press the button until it clicks, then restore power.

Many jet pump motors have a thermal overload on the motor itself. If the motor shut off hot, let it cool for 20 to 30 minutes, check that the pump is primed and press the reset button on the end cap if it has one. See how to prime a well pump.

A control box that keeps tripping often has a failing capacitor. My guide on how to test a well pump capacitor walks you through it.

Resetting the breaker

A tripped breaker sits in the middle position. Push it fully off, then back on, and check any GFCI or fuse between the panel and the switch.

Reset it once. A breaker that trips again as soon as the pump starts is telling you about a short, a bad capacitor or a seized pump; see well pump keeps tripping the breaker.

When not to keep resetting

  • The same device trips again within minutes or hours.
  • The pump runs but the gauge will not rise.
  • You smell burning or see scorched contacts in the switch.
  • Water is cloudy, sandy or sputtering, which can mean a low water level.
  • The breaker trips the moment the pump starts.

Each of these points to a real fault. Work through my well pump not working checklist, or call a pump installer before a reset turns a small repair into a new pump.

Replacing an old switch? See how to replace a well pressure switch and pressure switch settings.

Frequently asked questions

How do I reset my well pump?

If your pressure switch has a lever, lift it to START and hold it until the gauge passes the cut in pressure, then let go. Otherwise, turn the breaker off for a minute and back on, and check for a reset button on the control box or pump protector.

How long do I hold the well pump reset lever?

Hold it until the gauge rises past the cut in pressure, usually under a minute. If the pressure does not rise within about a minute, let go and look for a dry well, lost prime or a broken pipe.

Why does my well pump keep needing a reset?

Common causes are a leak, a low water level, a clogged pressure switch tube, a worn pump or frequent power cuts. Find the cause, because repeated resets can damage the pump.

Where is the reset button on a well pump?

Most well pumps do not have one on the pump. The reset is usually the lever on the pressure switch, a button on the control box or pump protector, or a thermal reset on a jet pump motor.

Does a submersible well pump have a reset button?

The pump itself does not, because it sits down in the well. The reset is at the house: the pressure switch lever, the control box, the drive or the breaker.

Is it safe to reset a well pump myself?

Lifting the pressure switch lever and resetting the breaker are safe for most homeowners. Turn the power off before opening any cover, and call a pump installer for electrical testing.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *