How to Test a Well Pump Capacitor (With a Reading Checker)
- Only 3 wire pumps have a capacitor in an above ground control box.
- A pump that hums but will not start is the classic sign of a bad start capacitor or relay.
- Use the capacitor checker below to compare your reading with the label.
A start capacitor gives a single phase pump motor the extra kick it needs to get turning. When it weakens, the pump hums, struggles or trips the breaker, and the part itself is cheap to replace.
I will walk you through finding it, testing it two ways and reading the result. You need a multimeter, insulated gloves and about 20 minutes.
Where the capacitor is (and when there is none)
On a 3 wire submersible pump, the start capacitor sits in the control box, usually mounted on the wall near the pressure tank. Larger control boxes, such as Franklin’s CSCR boxes, also hold a run capacitor next to it.
A 2 wire pump has no control box above ground, so there is nothing to test at the tank. If you are not sure which one you have, count the wires going down the well or read our 2 wire vs 3 wire well pump guide.
Jet pumps in a basement or pump house often have the capacitor on the motor itself, under a small cover. The same tests apply.
Signs of a bad well pump capacitor
| What you notice | Could be the capacitor? | Also check |
|---|---|---|
| Pump hums but will not start | Yes, very common | Relay, low voltage, stuck pump |
| Breaker trips as the pump starts | Sometimes (shorted capacitor) | Cable splice, motor windings |
| Slow starts, lights dim | Yes, a weak capacitor | Undersized wire, low voltage |
| Bulged, cracked or leaking case | Yes, it has failed | Look for heat damage in the box |
| Pump runs but no water | Rarely | See well pump not working |
If the breaker trips, read why a well pump keeps tripping the breaker first. A shorted cable can look a lot like a bad capacitor.
Safety first
- Turn off the pump breaker and confirm the pump will not run.
- Wait at least 5 minutes.
- Open the control box and check with your meter that there is no voltage across the capacitor terminals.
- Take a photo of the wiring, then disconnect the capacitor leads.
Capacitor checker
Enter the rating printed on the capacitor and your meter reading. Start capacitors are usually labeled with a range, such as 59 to 71 MFD, while run capacitors often show one value with a tolerance like ±6%.
Well pump capacitor checker
MFD and µF mean the same unit, microfarads. Always go by the label on your own capacitor, not by the example numbers above.
Test with a capacitance meter
This is the most useful test, because it tells you how much capacitance is left. Most mid range multimeters have a capacitance setting marked with the capacitor symbol.
- With the power off and the capacitor disconnected, set the meter to capacitance.
- Touch one probe to each terminal and wait for the reading to settle.
- Compare the number with the range on the label, or use the checker above.
- If it reads inside the range, the capacitor is fine and the problem is elsewhere.
- If it reads low or zero, replace it.
If your meter has no capacitance setting, a basic one with it costs little. See multimeters with a capacitance setting on Amazon.
Test with an ohmmeter
Franklin Electric’s AIM manual describes a quick ohmmeter check. Set an analog meter to R x 1,000 and touch the capacitor terminals: the pointer should swing toward zero and then drift back toward infinity.
A digital meter shows the same thing as a resistance that climbs after the probes touch. If it stays at zero, the capacitor is shorted, and if nothing moves at all, it is open.
The manual adds a warning: a capacitor can pass this test and still have lost capacitance. That is why I prefer the capacitance meter test whenever you have one.
Replacing a bad capacitor
- Match the rating. Use the same MFD range and the same or higher voltage rating as the old one.
- Use the right part number. Control box makers list the exact capacitor for each box and horsepower on a label inside the cover.
- Check the relay too. A burned relay can kill a new capacitor, so look for scorched contacts.
- Consider a new control box if the box is old, burned or the parts are hard to find. It must match the pump’s horsepower and voltage.
See Franklin QD control boxes on Amazon
If a new capacitor does not fix it, the motor or cable down the well may be failing. Our signs your well pump is going bad and well pump replacement cost guides help you plan the next step.
Frequently asked questions
How do I know if my well pump capacitor is bad?
The pump hums but will not start, starts slowly or trips the breaker, and the capacitor reads below its rated range on a capacitance meter. A bulged or leaking case also means it has failed.
Does a 2 wire well pump have a capacitor?
Not one you can reach. A 2 wire pump has no control box above ground, so there is no capacitor to test at the pressure tank.
Can I test a capacitor without removing it?
You should at least disconnect one lead. Other parts in the circuit can throw off the reading, and a disconnected capacitor is safer to handle.
What does MFD mean on a capacitor?
MFD stands for microfarads, the same unit as µF. Start capacitors usually show a range, and run capacitors usually show one value with a tolerance.
Can a bad capacitor damage a well pump?
A pump that keeps trying to start on a failed capacitor draws high current and heats the motor. Fix it quickly and let the pump protection devices do their job.
Sources
- Franklin Electric, Application, Installation and Maintenance (AIM) Manual, Submersible Systems, 60 Hz, 2026 (5 minute discharge warning, ohmmeter test, QD control box parts)
- R.C. Worst, How to Troubleshoot Franklin Electric Control Boxes
- InspectAPedia, motor capacitor tests
Related: well pump protection devices · pressure switch settings · 2 wire vs 3 wire pumps