Well Pump Check Valve: Where It Goes, Signs It Is Bad and How to Test It
Boreholeflow is reader supported. When you buy through links on this page, I may earn a commission at no extra cost to you. Read the full disclosure.
- A check valve is a one way valve that stops water in the drop pipe from running back down the well when the pump stops.
- Most submersible pumps have one built in at the pump. Common guidance adds one within 25 feet above the pump and another every 200 feet or less in deep wells.
- Signs of a bad check valve: the pump starts with no taps on, the gauge falls overnight, banging pipes and longer run times.
- Use spring loaded check valves in a well, not swing check valves, which close slowly and can cause water hammer.
The check valve is a small part that does a big job. It holds the column of water in your drop pipe so the pump does not have to lift it from scratch every time it starts.
When a check valve leaks, the symptoms look like other faults: short cycling, falling pressure and banging pipes. This guide explains what check valves do, where they go, how to test one and what replacing it involves, with a planner for your well depth.
Check valve planner and symptom checker
Check valve planner and symptom checker
Enter how deep your submersible is set and tick what you notice. We show where check valves usually go and what your symptoms point to.
What a well pump check valve does
When a submersible pump stops, the water in the drop pipe wants to fall back into the well. The check valve snaps shut and holds that water in place, so the pipe stays full and the pressure tank keeps its pressure.
- It keeps pressure in the system between pump cycles.
- It prevents backspin. Water rushing back down can spin the pump in reverse.
- It prevents upthrust. If the pump starts against an empty pipe, the impellers can lift and wear.
- It reduces water hammer by stopping the water column from dropping and slamming back.
Backspin, upthrust and water hammer effects as described by R.C. Worst, a pump distributor.
Where check valves go in a well
Most submersible pumps have a check valve built into the discharge head. Common guidance adds a second valve in the drop pipe within 25 feet of the pump, below the lowest pumping water level, so the water column is still held if the first one fails.
In deep wells, more valves go in at intervals of 200 feet or less to spread the weight of the water. Many well codes also want one above ground near the pressure tank, according to Boshart.
| Pump setting depth | Typical check valves in the well |
|---|---|
| Up to about 200 ft | Built in valve plus one within 25 ft above the pump |
| 200 to 400 ft | Built in, one within 25 ft, one about 200 ft higher |
| 400 to 600 ft | Built in, one within 25 ft, then every 200 ft |
Spacing from Boshart and R.C. Worst. Always follow your pump maker’s manual and local code.
Not sure how deep your pump sits? My how deep is my well guide shows how to find out from records or the wire length.
Spring loaded vs swing check valves
| Spring loaded (poppet) | Swing check | |
|---|---|---|
| How it closes | A spring snaps it shut as flow stops | A flap falls shut by gravity |
| Speed | Fast | Slow |
| Water hammer | Low | Higher, as water reverses before it closes |
| Use in a well | Yes, the standard choice | Not recommended in drop pipes |
Pick a brass, stainless or lead free bronze valve sized to your pipe, with a pressure rating above your pump’s maximum pressure. Plastic valves are fine for shallow, low pressure jobs only.
See spring check valves on Amazon
Signs of a bad check valve
- The pump starts with no taps running. Pressure leaks back down the well until the switch cuts in.
- The gauge falls overnight when nothing is running.
- Banging or thumping pipes when the pump starts or stops.
- Longer run times, because the pump refills a drained pipe each time.
- Air spitting from taps after the pump starts.
- A pump that hums or will not start after backspin damage, in bad cases.
These signs overlap with a leaking toilet, a waterlogged tank or a split pipe. Rule those out with the test below, and see well pump short cycling and well pump making noise.
How to test a check valve
- Let the pump fill the tank to its cut out pressure.
- Turn off the pump at the breaker so it cannot restart.
- Close the main valve after the tank to the house, if you have one. This rules out leaks in the house.
- Note the gauge reading and leave it for 30 to 60 minutes without using water.
- Read the gauge again. A steady reading means the valves and pipes hold. A falling reading means water is escaping between the pump and the tank valve.
If pressure falls and you have an above ground check valve, close a valve between it and the tank to see which side leaks. A leak on the well side usually means a check valve or a hole in the drop pipe down the well.
Replacing a check valve
An above ground check valve near the tank is a simple swap once the system is drained; see how to drain a pressure tank. A valve down the well means pulling the pump, pipe and wire, which is a job for a pump installer on deep wells.
If the pump has to come up anyway, it is a good time to check the wire and pump condition. My signs your well pump is going bad and well pump replacement cost guides help you decide whether to repair or replace.
Foot valves on jet pumps
A shallow well jet pump uses a foot valve at the bottom of the suction pipe. It is a check valve with a strainer, and it keeps the suction line full so the pump holds its prime.
A leaking foot valve is the usual reason a jet pump loses prime. See how to prime a well pump and jet pump vs submersible pump.
Frequently asked questions
Does a submersible well pump need a check valve?
Yes. Most have one built in, and common guidance adds another within 25 feet above the pump, plus more every 200 feet in deep wells.
How do I know if my well check valve is bad?
Common signs are the pump starting when no water is used, pressure dropping overnight, banging pipes and longer run times. Confirm with a pressure hold test.
Where should a check valve be on a well pump?
Within 25 feet above the pump in the drop pipe, below the lowest pumping water level, plus one every 200 feet or less in deep wells. Some codes also want one near the pressure tank.
Can a bad check valve cause short cycling?
Yes. If water leaks back down the well, pressure falls and the pump restarts even when no taps are on.
Should I use a swing check valve on a well?
Not in the drop pipe. Spring loaded check valves close faster and cause less water hammer.
How long does a well check valve last?
Many last as long as the pump, but sand and grit can wear them sooner. Replace in well valves whenever the pump is pulled if they show wear.